14 Technical Data
SMA Solar Technology AG
98
STP10-17TL-IA-en-32
Installation Manual
General Data
* VDE-AR-N-4105: valid from Firmware Version 2.31. Setting in accordance with VDE-ARN-4105 (Germany)
NRS 97-2-1: This standard stipulates that a special sticker be attached to the AC distribution to draw attention to the AC-side
disconnection of the inverter in case of grid failure (for more details, see NRS 97-2-1, Sec. 4.2.7.1 and 4.2.7.2)
C10/11: Only possible if the three-phase nominal voltage of the phase conductor is 400 V
EN 50438: Does not apply to all country standard deviations of EN 50438.
IEC 62109-2: This standard requires either that the multi-function relay is used as a fault indicator or that the inverter is registered
with the Sunny Portal and the error alarm is activated in the Sunny Portal.
Width x height x depth with
Electronic Solar Switch
665 mm x 690 mm x 265 mm
Weight
59 kg
Length x width x height of packaging
780 mm x 380 mm x 790 mm
Transport weight
65 kg
Climatic class in accordance with
IEC 60721-3-4
4K4H
Environment category
Outdoors
Degree of pollution outside the enclosure
3
Degree of pollution inside the enclosure
2
Operating temperature range
− 25°C to +60°C
Maximum permissible value for relative humidity,
non-condensing
100%
Maximum operating altitude above MSL
3,000 m
Power loss in night mode
< 1 W
Topology
transformerless
Cooling concept
OptiCool: temperature-controlled fan
Fan connection
designed for safe disconnection in accordance
with DIN EN 50178:1998-04
Degree of protection according to IEC 60529
IP65
Protection class (according to IEC 62103)
I
Country standards, as of 04/2013*
VDE-AR-N4105, VDE 0126-1-1, AS4777,
C10/11, PPDS, GBT19939-2005,
UTE C15-712-1, PPC, NRS 97-2-1, EN50438,
RD661/2007, IEC 61727, G59/2, CEI 0-21,
BDEW 2008, RD1699:2011, SI4777,
NEN EN 50438, DIN EN 62109-1,
IEC 62109-2