beautypg.com

SMA STP 10000TL-10 Installation User Manual

Page 60

background image

8  Configuration

SMA Solar Technology AG

60

STP10-17TL-IA-en-32

Installation Manual

8.3 Activating the Intelligent String Failure Detection

The intelligent string failure detection process is deactivated by default. You can activate the string
failure detection by setting a parameter via communication (e.g. Sunny WebBox or Sunny Explorer).
To do this, you will need the installer password.

Activating or Deactivating String Failure Detection

Resetting the Operating Data for String Failure Detection

Parameter

Setting

Description

Op.PvProMod/
Operating mode of
string failure detection

Stop

String failure detection deactivated

StrgFltDet/
Detect string failures

String-failure detection activated

PaStrgFltDet/
Detect sub-string
failures

String and sub-string failure detection
activated

Parameter

Description

Op.PvValRsIstl/
Reset operating data for
string failure detection

Restart of learning phase
Operating data for string failure detection are reset.

This manual is related to the following products: