6  Electrical Connection

SMA Solar Technology AG

44

STP10-17TL-IA-en-32

Installation Manual

9. If the Sunny Tripower does not beep or display an

error message, disconnect the Electronic Solar
Switch.
☑ The display switches off.

☑ You can now commission the inverter (see Section 7 "Commissioning", page 56). The following

connections and settings are optional.

6.5 Setting the Country Standard and Display Language

The inverter can be configured for various countries. This is carried out via the two rotary switches in
the inverter prior to commissioning, or by configuring the "CntrySet" or "Set country standard"
parameter via a communication product (e.g. Sunny WebBox or Sunny Explorer) once you have
commissioned the inverter.
The switch position 0/0 indicates the state upon delivery. The country settings were preset at the
factory via a communication product if you ordered the inverter with specific country settings. In this
case, you will not be able to recognise the current setting by the switch position. If changes are made
via the rotary switches or via a communication product, the default grid parameters are overwritten.
They cannot be restored, and must be re-entered via a communication product. The display language
can be changed at any time using the rotary switches, independent of the grid parameters. This means
that the default grid parameters remain unchanged, but the display messages are shown in the set
language. For devices ordered without any specified country of installation, the standard setting is
"VDE0126-1-1" and the language is German.
Changes will be accepted immediately after switching the miniature circuit-breaker on. If a

non-programmed switch setting is selected, the inverter issues an error message on the display and
the last valid setting is retained.