6  Electrical Connection

SMA America, LLC

34

SI_TDBOX-IA-eng-IUS122211

Installation Manual

D

Connecting terminal
blocks"Load L1", "Load L2"

with spring clamp terminals

Black/red For connecting L1 and L2 of the AC

sub-distribution for the loads

E

Connecting terminal blocks
"Neutral N" with spring clamp
terminals

Gray

For connecting N of the AC sub-
distribution for the loads, the PV plant,
the Sunny Island, and the generator or
the power distribution grid

F

Connecting terminal blocks
"Sunny Island AC2 L"

with

spring clamp terminals

Black

For connecting L of the AC 2 terminal of
Sunny Island

G

Connecting terminal blocks
"Sunny Island AC1 L"

with

spring clamp terminals

Black

For connecting L of the AC 1 terminal of
Sunny Island

H

2-pole miniature circuit-breaker
"F6" and "F7" with screw
terminals
"Grid or Generator L/L1",
"Grid or Generator L2"

Black/red For connecting L or L1 and L2 of the

generator or for connecting L1 and L2 of
the power distribution grid

I

2-pole miniature circuit-breaker
"F4" and "F5" with screw
terminals "Sunny Boy L1",
"Sunny Boy L2"

Black/red For connecting L1 and L2 of the PV plant

K

2-pole miniature circuit-breaker
"F2" and "F3"

See Section 4.5

L

1-pole miniature circuit-breaker
"F1"

See Section 4.5

M

Bypass switch

See Section 4.3

N

Overload protection

See Section 4.6

O

Contact hazard protection
cover*

Contact hazard protection cover with
6 anchorage points

* The contact hazard protection cover is shown as semi-transparent.

Position

Description

Color

Explanation