beautypg.com

8 opening and closing, 1 opening the sunny boy, Opening and closing – SMA SB 6000TL‑US Installation User Manual

Page 55: Opening the sunny boy

background image

SMA America, LLC

8  Opening and Closing

Installation Manual

SB6-11TL-US-IA-en-13

55

8 Opening and Closing

8.1 Opening the Sunny Boy

1. Switch off all AC and DC breakers or switch-disconnectors. Ensure that the switches cannot be

inadvertently reconnected.

2. Wait at least 5 minutes until the residual voltage has been drained.
3. Remove the 6 screws and conical spring washers from the enclosure lid. Pull the lid smoothly off

forwards.

4. Put the cover, screws, and washers aside.

☑ The Sunny Boy is open.

High voltages are present in the Sunny Boy during operation
Death or serious injury due to electric shock.

• Only open the Sunny Boy in the order described as follows.

5.

Moisture can penetrate the open Sunny Boy
Potential damage to the Sunny Boy.

• Do not open the Sunny Boy in the event of rain or a high level of humidity (>95%).
• Handle the enclosure lid with care.

Damage to the seal of the enclosure lid during frost
When opening the Sunny Boy during frost, the seal of the enclosure lid can be damaged. There
may be an ingress of moisture damaging the Sunny Boy.

• Do not open the Sunny Boy when the outdoor temperature is below 23°F ( − 5°C).

Electrostatic discharges through touching component parts
Potential damage to the Sunny Boy.

• Ground yourself prior to touching a component part.