beautypg.com

2 requirements for the mounting location, Requirements for the mounting location – SMA SB 6000TL‑US Installation User Manual

Page 20

background image

4  Mounting

SMA America, LLC

20

SB6-11TL-US-IA-en-13

Installation Manual

4.2 Requirements for the Mounting Location

Requirements

☐ The installation method and mounting location must be suitable for the weight and dimensions

of the Sunny Boy (see Section 11 "Technical Data", page 70).

☐ Note the dimensions of the DC Disconnect (4.3 "Mounting the DC Disconnect", page 25).
☐ Mount the inverter on a stable surface.
☐ The mounting location must be accessible at all times.

☐ Mount vertically or tilted backward at max. 15°.
☐ The connection area must point downward.
☐ Do not install the inverter tilting forward.
☐ Do not install the inverter horizontally.
☐ Install the inverter at eye level in order to be able to read out the operating state at any time.
☐ The ambient temperature must be in a permissable range ("Technical Data" on page 70).
☐ Do not expose the inverter to direct sunlight.
☐ In the living area, do not mount inverters on a

plasterboard wall or similar wall.
The Sunny Boy may emit noises when in use which
can be regarded as a nuisance.