2 sunny boy 7000/7700tl-us – SMA SB 3000TL-US Installation User Manual
Page 73
SMA America, LLC
11 Troubleshooting
Installation Manual
SB3-5TLUS22-IA-en-16
73
9. Insert the fan with fan casing into the enclosure
opening. The arrow on the fan casing must point
towards the display.
10. Hook the locking tabs on the right-hand side of the fan casing underneath the wall of the
enclosure and press the fan with fan casing into the enclosure opening.
☑ The left-hand locking tabs snap into place.
11. Flip the display down and fasten the screw
hand-tight.
12. Close the inverter and recommission it (see Section 7 "Commissioning", page 47).
11.4.2 Sunny Boy 7000/7700TL-US
Disassembling the Fan
1. Disconnect the inverter from any voltage sources (see Section 10 "Disconnecting the Inverter
from Voltage Sources", page 55).
2. Wait for the fan to stop rotating.
3. Grab behind the inverter from the bottom side.
Push on the locking tab on the right next to the fan
guard and at the same time slide the fan out from
the left to the right side.