4.2 DC Disconnect

The DC Disconnect is a DC load-break switch which safely disconnects the PV array from the inverter.

Figure 3: DC Disconnect design

Symbols on the DC Disconnect

Item

Description

A

Bracket for grounding the DC Disconnect enclosure

B

Rubber grommet for the enclosure opening

C

Bracket for hanging in the retainer

D

Type label 1

E

Conduit knockouts

F

Type label 2

G

Enclosure lid screws

H

Enclosure lid

I

Switch

Symbol

Description

Explanation

Equipment grounding
conductor terminal

Connection for the DC equipment
grounding conductors