11 Troubleshooting

11.1 Event Messages

Display message

Cause

AFCI self-test successful

The inverter has successfully performed the arc fault detection
self-test.

Backup mode on

The inverter is operating in grid parallel operation with adjusted
grid monitoring.

Grid guard code valid

The SMA Grid Guard code entered is valid. Protected parameters
have now been unblocked and you can adjust the parameters.
The parameters will be automatically locked again after
10 feed-in hours.

No new update SDcard

There are no update files relevant for this inverter on the SD card
or the available update has already been carried out.

Grid param.unchanged

The selected rotary switch position is not assigned or it is not
possible to change the grid parameters.

Parameters set successfully

A new country data set has been configured.

SD card is read

The inverter is currently reading the SD card.

Self-test

The self-test is being carried out.

Set parameter

The inverter is setting the parameters.

Standalone op.

The inverter is operating in the secure power supply operation.

Update completed

The inverter has successfully completed the update.

Update main CPU

The inverter is performing an update of the inverter components.

Update communication

The inverter is performing an update of the communications
components.

Update RS485I module

The inverter is updating the RS485i module.

Update Speedwire

The inverter is updating the Speedwire module.

Upd. language table

The inverter is updating the language table.

Update Webconnect

The inverter is updating the Webconnect module.

Update file OK

The update file found is valid.