86

FM-3 Programming Module Reference Manual

Jog View

Jogging produces rotation of the motor at controlled velocities in a positive or negative
direction. The jog is initiated with the Jog.#.Initiate destination or from a program.

Figure 53:

Jog View

Jog Number

This scroll box allows you to select between Jog0 and Jog1 setup views.

Jog Name

This is a descriptive character string which can be assigned to the specific jog. Giving a name
to a jog can make the motion setup easier to follow.

Time Base

This list box allows the user to select between a jog that is based on time (Realtime) as defined
by user units, normally in seconds, or a time based on Master position via an external encoder