72

K2 Summit Production Client Service Manual

09 April 2010

Chapter 3 Service Procedures

procedure.

5. Remove the CompactFlash boot media from the K2 Summit Client.

If the USB Recovery Flash Drive is in the USB port on the front bezel assembly,
you can remove the front bezel assembly to access the CompactFlash boot media.
Doing so does not disrupt the Acronis True Image program.

6. Insert the blank CompactFlash boot media into the K2 Summit Client.

7. Restore the image to the blank CompactFlash boot media.

This is now the Recovery CompactFlash boot media for that particular K2 Summit
Client.

8. Remove the Recovery CompactFlash boot media from the K2 Summit Client.

9. Insert the original CompactFlash boot media into the K2 Summit Client.

10. Click

Operations | Exit

to exit the Acronis True Image program.

The K2 Summit Client restarts automatically.

11. Remove the USB Recovery Flash Drive while the K2 Summit Client is shutting

down.

12. Store the Recovery CompactFlash boot media in a place where it can be retrieved

quickly and easily identified with the K2 Summit Client it restores.

13. If a system fault occurs and you need to restore the K2 Summit Client, you can do

so using the Recovery CompactFlash boot media as follows:

a. Shutdown the K2 Summit Client.

b. Exchange the current CompactFlash boot media with the K2 Summit Client’s

Recovery CompactFlash boot media.

NOTE: On an individual K2 Summit Client use only the Recovery CompactFlash
boot media prepared for that specific K2 Summit Client. Do not attempt to use the
Recovery CompactFlash boot media from a different K2 Summit Client.

c. Start up the K2 Summit Client.

The K2 Summit Client boots from the Recovery CompactFlash boot media with
the system intact as it existed when you created the Recovery CompactFlash boot
media.

Installing the Fibre Channel card driver

If your K2 Summit Client has the optional Fibre Channel card, the driver for the Fibre
Channel card is not on the recovery image provided by Grass Valley for that K2
Summit Client. Therefore, after restoring the image, you must install the Fibre
Channel card driver as instructed in this procedure.

1. Make sure that you have access to the Fibre Channel card driver file. On the local

K2 Summit Client, in C:\Windows look for LSI_SCSIPORT_1.21.25.00, then do
one of the following:

• If the file is present, continue with the next step in this procedure.