beautypg.com

About networking – Grass Valley K2 Summit Client Service Manual May.14 2010 User Manual

Page 54

background image

54

K2 Summit Production Client Service Manual

09 April 2010

Chapter 3 Service Procedures

Refer to

“Disk module removal” on page 95

for the mechanical procedure for

removing and inserting a drive.

On inserting a RAID 1 replacement drive, if disk access (record/play operations) is
underway, the RAID controller automatically starts rebuilding the drive. You can
verify rebuild status by looking at the drive LED or by looking at the Service LED.
Refer to

“Front panel indicators” on page 38

. If there is no media access currently

underway, you can use Storage Utility to force-start the rebuild process.

You can also check disk status in the Storage Utility by selecting the disk module icon
in the device tree. Status is reported in the right-hand pane. On completion, the disk
drive status changes from Rebuilding to Online. You may need to refresh the Storage
Utility display. You can also open the Progress dialog box, by clicking

View | Progress

Report

.

About networking

When you receive a K2 Summit Client from the factory, it has a specific network
configuration, including a loopback adapter and two of the four Gigabit Ethernet ports
configured as a teamed pair. The Gigabit Ethernet ports, as viewed when looking at
the rear panel, are represented in the following illustration.

1

2 3

4

Control Team: Same for internal, direct-
connect, and SAN storage.

iSCSI:
SAN
storage

iSCSI:
Redundant
SAN
storage

Control:
Internal,
direct-
connect,
and SAN
storage

Control:
Redundant
SAN
storage

FTP/Streaming:

Internal and

direct-connect

storage

Media

Connection #1

Control

Connection #1

Control

Connection #2

Media

Connection #2