8995UPC/DNC/UDX — Instruction Manual

Configuration

Genlock Web Page

Use
this
link

The Genlock web page (

Figure 54 on page 89

) is present on 8995 links when

an 8900GEN-SM submodule is installed on the module.

Refer to the 8900GEN-SM Installation Manual available online for complete
details for configuring the 8900GEN-SM submodule. Also refer to

Genlock

Submodule Installation on page 16

for installation information.

This web page provides reporting status for the following genlock status
items:

Genlock – reports status of Genlock function as

Enabled

or

Freerun

.

Status – reports whether the reference input is

Locked

or

Not Locked

.

Firmware Version – reports the firmware version of the 8900GEN-SM
submodule installed on this 8995 module.

Hardware Revision – reports the hardware version of the 8900GEN-SM
submodule installed on this 8995 module.

Ref Input Standard – reports the reference input standard as detected
by the 8900GEN-SM submodule that is connected to the Genlock Loop
on the 8900GFR-R rear module.

Ref Input Frame Rate – reports the frame rate of the reference input as
detected by the submodule.

Output Bus Frame Rate – reports the frame rate being output on the
frame bus.

Output Bus – reports the reference bus (Ref Bus 1 or Ref Bus 2) being
output from the submodule.

Genlock Control

The following controls are available for configuring the Genlock sub-
module:

Enable

or

Freerun

– select one of the radio buttons to enable the Genlock

submodule or allow the reference to freerun.

Input Standard Selection

– use this control to set the input standard needed

for the reference input. Refer to

Loop Bandwidth

– set this control for either fast locking (

Fast Lock

) to the

reference or for the lowest jitter performance (

Low Jitter

) depending on

the stability of the reference signal being used.


For example, if Low Jitter is selected and the Status is still

Invalid

after

one minute has passed, the input reference has excessive wander that
cannot be tracked in Low Jitter mode. Switch to

Fast Lock

and verify

Status is

Locked

after about 10 seconds.