8995UPC/DNC/UDX — Instruction Manual

17

Installation

Frame Bus Jumpering

If you will be using this 8995 module to distribute reference Frame Bus 1
(slot 1) or Frame Bus 2 (slot 3), you must set a jumper on the front module
circuit board for this purpose before installing the module (

Figure 4

).

Frame Bus 1 – to transmit the reference connected to one of the Genlock
Loop BNCs on the corresponding rear module on Frame Bus 1, set
jumper J11 to

ENA

(pins 1-2). This module must be installed in slot 1 of

the frame and configured on the Genlock web page (see

Genlock Web

Page on page 88

) for

Auto

in the Drive Frame Reference Bus pulldown.

Frame Bus 2 – to transmit the reference connected to one of the Genlock
Loop BNCs on the corresponding rear module on Frame Bus 2, set
jumper J10 to

ENA

(pins 1-2). This module must be installed in slot 3 of

the frame and configured on the Genlock web page (see

Genlock Web

Page on page 88

) for

Auto

in the Drive Frame Reference Bus pulldown.

Note

Both jumpers may be enabled. The module in slot 1 will only read the status
of jumper, J11. The module in slot 3 will only read the status of jumper, J10.

Figure 4. Setting Frame Bus Jumpers

For Frame Bus 2 distribution, set
GENLOCK BUS XMT jumper, J10
Pins 1-2 (ENA) or pins 2-3 (DIS).

For Frame Bus 1 distribution, set
GEN LOCK BUS XMT jumper, J11
Pins 1-2 (ENA) or pins 2-3 (DIS).

8480_03r1

Pin 1

Pin 1