8995UPC/DNC/UDX — Instruction Manual

Configuration Summary Table

Select type of output processing for
In1 and In2 in Channel A and Chan-
nel B in each Stream in each Group
(1-4).

Stream 1 ChA=In1
Stream 2 ChB=In2

In1,

-In1,

In2,

-In2,

In1+In2,

- (In1+In2),

In1-In2,

- (In1-In2),

1kHz,

400 Hz,

Silence, or

ID.

Audio Proc/

Audio Re-Embedding to SDI Output

Group 1

Stream 1: ChA and ChB (In1 and In2)
Stream 2: ChA and ChB (In1 and In2)

Group 2

Stream 3: ChA and ChB (In1 and In2)
Stream 4: ChA and ChB (In1 and In2)

Group 3

Stream 5: ChA and ChB (In1 and In2)
Stream 6: ChA and ChB (In1 and In2)

Group 3

Stream 7: ChA and ChB (In1 and In2)
Stream 8: ChA and ChB (In1 and In2)

N/A

Genlock Enable

Enable

Enable or Freerun

Genlock/

Genlock Control

Enable or Freerun radio button

GLEnable

Genlock Input Standard Selection

NTSC

NTSC,

PAL,

1080i 59.95,

720p 59.94,

1080i 50,

720p 50,

1080p 24,

1080sF 24,

1080p 23.98,

AES 48K,
AES 96K,

Word Clock 48K,

or Work Clock 96K.

Genlock/

Genlock Control

Input Standard Selection pulldown

GLInSel

Select loop bandwidth

Fast Lock

Low Jitter or Fast Lock

Genlock/

Genlock Control

Loop Bandwidth radio button

GLLoopBW

Set Line offset for Genlock timing

0

525 rates: 0 to 524
625 rates: 0 to 624

Genlock/

Genlock bus Timing

Line Offset control

GLLnOff

Set Coarse Offset for Genlock timing

0

525 rates: 0 to 1715
625 rates: 0 to 1727

Genlock/

Genlock bus Timing

Coarse Offset (37ns) control

GLcors

Set Genlock fine offset timing

0

0 to 255

Genlock/

Genlock bus Timing

Fine Offset (37ns/256) control

GLfine

Set Genlock audio frame offset tim-
ing

0

0 to 4

Genlock/

Genlock Bus Timing

Audio Frame Offset control

GLAESFrm

Select Genlock drive frame reference
bus

Auto

Off or Auto

Genlock/

Drive Frame Reference Bus pulldown

GLBusDr

Recall factory default parameters

N/A

See Defaults column

User Settings/

Recall Factory Defaults

Set Factory Defaults button

N/A

Recall factory names

N/A

See I/O Config web page

User Settings/

Recall Factory Defaults

Set Factory Names button

N/A

Table 13. Summary of 8995UDX/UPC/DNC Configuration Functions

Function

Type

Default

Range/Choices

Resolution

Web Page/

Function Name

Newton