Grass Valley 8995DNC v.1.3.0 User Manual
Page 25

8995UPC/DNC/UDX — Instruction Manual
25
Power Up
Table 2. Board Edge LED Names and Meaning
LED
Indication
Condition
FAULT
(red)
Off
Normal operation.
On continuously
Module has detected an internal fault.
Flashing
Configuration problems. Check inputs and settings. Missing video.
COMM
(yellow)
Off
No activity on frame communication bus.
3 Quick Pulses
Locate Module command received by the module from a remote control system.
Short flash
Activity present on the frame communication bus.
CONF
(yellow)
Off
Module is in normal operating mode.
On continuously
Module is initializing, changing operating modes or programming hardware.
PWR
(green)
Off
No power to module or module’s DC/DC converter failed.
On continuously
Normal operation, module is powered.
FRM1
(green)
Off
Reference frame bus is disabled to frame on Genlock web page or no Genlock submodule is installed in slot 1.
On
Reference frame bus is enabled on Genlock web page and Genlock submodule is installed in slot 1.
FRM2
(green)
Off
Reference frame bus is disabled to frame on Genlock web page or no Genlock submodule is installed in slot 3.
On
Reference frame bus is enabled on Genlock web page and Genlock submodule is installed in slot 3.
VID IN
(green)
Off
Indicates no valid input signal is being detected.
On
Indicates a valid input signal is being detected.
REF IN
(green)
Off
Indicates no valid reference signal is being detected or signal is not locked.
On
Indicates a valid reference signal is present and locked.