Configuring the time zone for user logs, Configuring user logging at the cli, User logging configuration task list – H3C Technologies H3C SecBlade LB Cards User Manual
Page 49: Configuring the user logging version
40
Configuring the time zone for user logs
User logs can be recorded in UTC or localtime:
•
UTC—Coordinated Universal Time, loosely defined as current date and time of day in Greenwich,
England.
•
Localtime—Coordinated Universal Time (UTC) plus the UTC offset.
To configure the time zone for user logs:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the system to record
user logs in localtime.
userlog flow export
timestamps localtime
Optional.
By default, userlogs are recorded in UTC.
Configuring user logging at the CLI
At the CLI, user logging is also known as "flow logging."
User logging configuration task list
Task Remarks
Configuring the user logging version
Optional.
Configuring the source address for user logging packets
Optional.
Exporting user logs to log servers
Required.
Use either method.
Exporting user logs to the information center
Configuring the user logging version
Configure the user logging version according to the receiver capability. A receiver cannot resolve user
logs correctly if it does not support the version of the user logs.
To configure the user logging version:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the user
logging version.
userlog flow export version
version-number
Optional.
The default version is 1.0.
Although the device supports two versions, only
one can be active at one time. Therefore, if you
configure the user logging version multiple
times, the most recent configuration takes effect.