Outputting system information to a log host

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable the information
center.

info-center enable

Optional.
Enabled by default.

3.

Name the channel with a
specified channel

number.

info-center channel channel-number
name channel-name

Optional.
See

Table 2

for default channel names.

4.

Configure an output rule
for the log host.

info-center source { module-name |
default } channel { channel-number

| channel-name } [ debug { level

severity | state state } * | log { level
severity | state state } * | trap { level

severity | state state } * ] *

Optional.
See "

Default output rules of system

information

."

5.

Specify the source IP
address for the log

information.

info-center loghost source
interface-type interface-number

Optional.
By default, the source IP address of
output log information is the primary IP

address of the matching route' egress
interface.

6.

Configure the timestamp

format for system
information output to the

log host.

info-center timestamp loghost { date
| iso | no-year-date | none }

Optional.
date by default.

7.

Set the format of the

system information sent
to a log host.

Set the format to UNICOM:

info-center format unicom

Set the format to H3C:

undo info-center format

Optional.
Use either approach.
H3C by default.

8.

Specify a log host and

configure related
parameters.

info-center loghost [ vpn-instance
vpn-instance-name ]
{ host-ipv4-address | ipv6

host-ipv6-address } [ port

port-number ] [ channel
{ channel-number | channel-name }

| facility local-number ] *

By default, no log host or related
parameters are specified.
If no channel is specified when

outputting system information to a log
host, the system uses channel 2

(loghost) by default.
The value of the port-number argument

must be the same as the value
configured on the log host. Otherwise,

the log host cannot receive system

information.

Outputting system information to the trap buffer

The trap buffer only receives trap information, and discards log and debug information.
To output system information to the trap buffer: