65

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable the information center. info-center enable

Optional.
Enabled by default.

3.

Name the channel with a

specified channel number.

info-center channel
channel-number name
channel-name

Optional.
See

Table 3

for default channel

names.

4.

Configure the channel
through which system

information can be output to

the Web interface.

info-center syslog channel
{ channel-number |

channel-name }

Optional.
By default, system information is
output to the Web interface

through channel 6.

5.

Configure a system

information output rule for the
Web interface.

info-center source { module-name |
default } channel { channel-number

| channel-name } [ debug { level
severity | state state }* | log { level

severity | state state }* | trap

{ level severity | state state }* ]*

Optional.
See "

Default output rules of system

information

."

6.

Configure the timestamp

format.

info-center timestamp { debugging
| log | trap } { boot | date | none }

Optional.
The timestamp format for log, trap

and debugging information is date
by default.

Configuring synchronous information output

The output of system logs interrupts ongoing configuration operations. You have to find the previously

input commands before the logs. Synchronous information output can show the previous input after log
output and a command prompt in command editing mode, or a [Y/N] string in interaction mode so you

can continue your operation from where you were stopped.
If system information, such as log information, is output before you input any information under the

current command line prompt, the system does not display the command line prompt after the system
information output.
If system information is output when you are inputting some interactive information (non Y/N

confirmation information), the system displays your previous input in a new line but does not display the

command line prompt.
To enable synchronous information output:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable synchronous
information output.

info-center synchronous

Disabled by default.