Overload operation is given, motor breaker trips – AEC Colortronic MS Series Screenless Granulator User Manual
Page 38
Chapter 8 Troubleshooting
- 33 -
[WO-3531;ET 33]
Overload operation is given, motor breaker trips
Check point
Remedy
Precaution
Check whether many runners
aren't being inserted in the feed
hopper.
Remove the runners inside the
feed hopper.
Do the work after the primary power
supply put off.
Insert a single runner only.
Check mixing of the different
material in the feed hopper and
granulator.
Remove the different material.
Then, exchange it when there is a
damage part.
Do the work after the primary power
supply put off.
To purchase the parts or exchange, please
contact our service division.
Check whether the granulating
ability doesn't down.
Repair the down cause of the
granulating ability.
Refer to this chapter. “The abnormal
sound on the operation comes out,
Power down of granulating ability.”
Check whether the bearing of
driving part is not over heating
condition.
Exchange the bearing.
Do the work after the primary power
supply put off.
To purchase the bearing or exchange,
please contact our service division.
Check whether the driving motor
starts normally.
Repair or exchange the driving
motor (geared motor).
To purchase the geared motor or exchange,
please contact our service division.
Check whether the power supply
code of driving motor isn’t
out.
Check whether there is looseness
in the connection part.
○
Tighten the connection part of
the power supply.
○
Exchange the power supply
code.
Do the work after the primary power
supply put off.