beautypg.com

Confirmation of each unit condition – AEC Colortronic MS Series Screenless Granulator User Manual

Page 25

background image

Chapter 5 Preparations for operation

- 20 -

[WO-3531;ET 20]

2. Confirmation of each unit condition

Confirmation unit

Contents of confirmation

Feed hopper

Confirm whether feed hopper is closed securely.
(Confirm the fastening condition of the feed hopper clamp)

NOTE

When feed hopper is open and when it isn't securely close.
The granulator can't start when either of two limit switch for the
closing confirmation is off.

Cutting chamber of the
granulator

Confirm whether cutting chamber of the granulator is closed securely.
(Confirm the fastening condition of the cutting chamber clamp)

NOTE

When cutting chamber of the granulator is open and when it isn't
securely close.
The granulator can't start when either of two limit switch for the
closing confirmation is off.

Suction box (KKB)

or suction box (SKB)

or

receive box

Confirm whether suction box (KKB)(or suction box (SKB) or receive box)
is being installed in discharge port of granulator lower part.

NOTE

Confirm whether the hinge bolt for the fixation is fastened.