Chapter 7 Maintenance and check

- 29 -

[WO-3531;ET 29]

5-3. How to gap adjust of rotating cutters and fixed cutters

Adjust the gap between the rotating cutters and fixed cutters to 0.2mm.

Step

Item

Description

Opening the feed hopper

Remove the clamp of feed hopper, turns round the side the hopper
is fallen, and opens slowly.

WARNING

It is pushed down slowly with keep feed hopper from the
down side when feed hopper is opened.
Don't insert a hand and a finger into stopper.
When feed hopper is closed, feed hopper lifted slowly.
At that time, be careful to insert a hand and a finger into
pinch point.
When a hand and a finger are inserted into pinch point, it
has the danger of lacerations and fracture.

Clamp of cutting
chamber

The clamp is to do the part of upper and lower the cutting chamber
of granulator without gap.
(Tighten the clamp of citting chamber completely)

Adjustment of the gap

The removed bolts of fixed cutters are tightened temporarily.

Hold and turned the width of 2 area of keeper plate with spanner or
monkey wrench.
Then, using the thickness gauge (the gap) does the adjustment of
interval.

Completing adjustment of the gap, tighten the fixed cutters on a
full scale.

WARNING

The work is doing carefully with wear the gloves.
For the sharp cutters, it has the danger that the hand and
the finger have the lacerations.