6618-3202
63
Register
Function
Range
Units
Saved
Default
Note
S8
Pause time
for comma
dial modifier
0–255
s
*
2
The function of the
“comma” separator depends
on the value assigned to
register S8. The value rep-
resents the pause duration
of the modem before dial-
ing the digit following the
comma in the dial
command line. The pause
time is expressed in units
of 1 second and ranges
from 0 to a maximumvalue
of 255.
In some countries the maxi-
mum value is limited.
If, country code sets a maxi-
mum value and, 2 or more
consecutive separators are
used, only the first will be
considered..
S10
Lost Carrier
To Hang Up
Delay
1–255
0.1 s
*
14
Register S10 determines the
delay time between the loss
of the carrier and when the
modem disconnects. This
delay allows the carrier to
drop momentarily without
causing a disconnect. The
register is given in 100 ms
units. Default = 14.
If you assign the value to
255 the carrier disconnect
function is disabled.
S11
DTMF Tone
Duration
50-255
ms
*
95
Country dependent.