beautypg.com

Westermo TDW-33 User Manual

Page 63

background image

6618-3202

63

Register

Function

Range

Units

Saved

Default

Note

S8

Pause time
for comma
dial modifier

0–255

s

*

2

The function of the
“comma” separator depends
on the value assigned to
register S8. The value rep-
resents the pause duration
of the modem before dial-
ing the digit following the
comma in the dial
command line. The pause
time is expressed in units
of 1 second and ranges
from 0 to a maximumvalue
of 255.
In some countries the maxi-
mum value is limited.
If, country code sets a maxi-
mum value and, 2 or more
consecutive separators are
used, only the first will be
considered..

S10

Lost Carrier
To Hang Up
Delay

1–255

0.1 s

*

14

Register S10 determines the
delay time between the loss
of the carrier and when the
modem disconnects. This
delay allows the carrier to
drop momentarily without
causing a disconnect. The
register is given in 100 ms
units. Default = 14.
If you assign the value to
255 the carrier disconnect
function is disabled.

S11

DTMF Tone
Duration

50-255

ms

*

95

Country dependent.
Can not be modified.