Westermo TDW-33 User Manual
Page 18

6618-3202
18
In – Request identification information
Supported by:
TDW-33
TD-36
TD-36 485
TR-36
TR-36B
Description:
This command causes the product to transmit one or more lines of specific information
text.
Syntax:
ATI
Parameters:
0:
Display max line speed.
1: Reserved
2: Reserved
3: Reserved
4:
Display manufacturer identification.
5:
Display country code.
6:
Display revision identification for modem modulation code
7: Reserved
8: Display switch settings
9:
Display Westermo Application Software revision identification.
Other values: “ERROR” string is sent back.
Command example Possible responses
Note
ATI0
33600
Max line speed
OK
ATI4
WESTERMO
Modem manufactor
TELEINDUSTRI
AB
identifier
OK
ATI6 BSMW310_BF533_bfbsmw310_5457OK
Revision
identification
OK
for modem modula-
tion code
ATI8
000 000 000 000
Switch settings
OK
Each DIP switch
displayed as a decimal
value. S1 S2 S3 S4
Notice switch setting
is only reed at power-
up and ATZ
ATI9 4101-0201
Westermo
SW
OK
release
ERROR
Otherwise
S register: None