Westermo TDW-33 User Manual
Page 60

6618-3202
60
Zn – Soft Reset
Supported by:
TDW-33
TD-36
TD-36 485
TR-36
TR-36B
Description:
This command do a soft reset and restores the configuration profile according to the
parameter supplied.
If no parameter is specified, zero is assumed.
Syntax:
ATZ
Parameters:
0: Soft reset, profile 0
1: Soft reset, profile 1
Command example
Possible responses
Note
ATZ
OK
ERROR
Otherwise
S register: None.
&Zn = x – Store Telephone Number
Supported by:
TDW-33
TD-36
TD-36 485
TR-36B
Description:
The modem can store up to four telephone numbers and each telephone number
dial string can contain up to 31 digits. Entry 0 is used for DTR and TxHotline call, see
AT&B
Syntax:
AT&Z
Parameters:
0:
Telephone number 0
1: Telephone number 1
2: Telephone number 2
3: Telephone number 3
Dial string from 0 to 31 characters
Command example
Possible responses
Note
AT&Z
OK
The number is stored
ERROR
Otherwise
S register: None.