Westermo TDW-33 User Manual
Page 62

6618-3202
62
Register
Function
Range
Units
Saved
Default
Note
S5
Backspace
Character
0–128
ASCII
*
8
S5 holds the ASCII value
of the back space control
character. The default value
is 8. The backspace char-
acter must not be set to
avalue corresponding to a
printable ASCII character
(which is between 33 and
126).
S6
Dial Delay
Blind dialing
0–255
s
*
3
This register programs
the pause time before
continuing the dial process.
(in case there is no wait-
ing for dialtone). Units is in
seconds. Maximum = 255.
Default = 3
S7 Wait
Time
for Carrier,
Silence, or
Dial Tone
0–255
s
*
50
This register gives the
answer tone and silence
timeout during dialing
before hanging up. Units is
in seconds. Maximum = 255.
Default = 50. In leased line
mode, this register is used
as synchronisation timeout
(answer tone – calling tone
synchronisation) between
the calling and answering
modem. If the timeout is
expired, the modem will
restart it's training until the
number of synchronization
attempts is reached.