*WI – Information string

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description

The command enable or disable the sending of an information string to the DTE or
remote DCE according to the parameter supplied. The parameter values, if valid, are
stored in the active profile.

Syntax:

AT*WI=<”string”>,

Parameters:

<”string”>

Information string [0-40 characters].

Information string mode [0-5].

0:

Disable the function

1:

Send information string to remote DCE when inactivity timer (S30) expires.

2:

Send information string to remote DCE after connect message or DCD.

3:

Send information string to DTE when inactivity timer (S30) expires.

4:

Send information string to DTE after connect message or DCD.

5:

Same as number 2 but with an extra CR.

Other values: “ERROR” string is sent back.

Command example

Possible responses

Note

AT* WI=”Info string 1”,1

OK

Send info string to

remote DCE when

inactivity timer expires.

AT* WI =”Info string”,4

OK

Send info string to DTE

when

connected.

AT* WI =””

OK

Delete info string and

disable

function

(mode to 0)

AT*WI=,0 OK

Disable

function

AT*WI=,1

OK

Enable function with

mode set to 1

AT* WI?

*WI: string, mode

List parameters

OK

AT* WI =?

* WI : (0-40 CHAR),

List command parameters

(0-255)
OK

ERROR

Otherwise

S register: See S30