Westermo TDW-33 User Manual
Page 12

6618-3202
12
%En – Enable/Disable Line Quality Monitor and Auto-Retrain or
Fallback/Fall Forward
Supported by:
TDW-33
TD-36
TD-36 485
TR-36
TR-36B
Description:
Enable/disable Line quality Monitor and Auto-Retrain or Fall back/fall forward.
This command controls if the modem automatically monitors the line quality and
requests a retrain (%E1) or fall back when line quality is insufficient or a fall forward
when line quality is sufficient (%E2). Set S41 bits 2 and 6.
Syntax:
AT%E
Parameters:
0:
Disable Line Quality and auto-retrain
1:
Enable Line Quality and auto-retrain
2:
Enable Line Quality Monitor and Fallback/Fall Forward / (Default)
Command example
Possible responses
Note
AT%E
The command is valid
and accepted
ERROR
Otherwise
S register: The value is written to S41 bits 2 and 6.