*WIOP – Generic I/O parameters

Supported by:

TD-36 485

TR-36B

Description:

This command set the I/O parameters.

Syntax:

AT*WIOP = ,,,,

AT*WIOP = ?

AT*WIOP?

Parameters:


Min trig pulse time in 10 ms increments [1-255].
This parameter sets the minimum time the pulse/level must be active.
A pulse shorter than this time will be skipped.


Pulse period time in 10 ms increments [1-255]
Sets the minimum time between pulses. The number of pulses will be calculated
when the time between pulses is longer than Tp. Note Tp must be longer than 2ta.


Trig source and type

0 = NO

Trigger not used

1 = LEVEL

Trigger source is the digital input level.

2 = PULSE

Trigger source is an edge on the digital input.

3 = DCD

Trigger internally coupled to reflect the DCD signal

4 = DTR

Trigger internally coupled to reflect the DTR signal

31 = DCD PSTN Trigger internally coupled to reflect the DCD signal on the PSTN
interface

32 = DCD LL

Trigger internally coupled to reflect the DCD signal on the

Leased Line interface


Trigger level

0 = NO

Trigger not used

1 = HIGH

Defines that a high level triggers the service

2 = LOW

Defines that a low level triggers the service

3 = POS

A positive edge triggers the service

4 = NEG

A negative edge triggers the service

5 = FLANK

A positive or negative flank triggers the service

6 = FLANK 2

A positive flank triggers service 1, a negative flank triggers service 2