Westermo TDW-33 User Manual
Page 55

6618-3202
55
Normal inactivated state of the output as well as the source controlling the output.
0 = NO
Output not used
1 = I/O operation Operation controlled by remote I/O Transparent or Out
2
Reserved
3 = DCD
Output will be controlled by DCD. An active DCD will activate the
output.
4 = DTR
Output will be controlled by DTR. An active DTR will activate the
output
31 = DCD PSTN Output is controlled by DCD on the PSTN interface
32 = DCD LL
Output is controlled by DCD on the Leased Line interface
Note! If LEVEL trigged input is programmed, all defined entries will be trigged.
Command example
Possible responses
Note
AT*WIOP = 50,100,1,1,3 OK
Command valid and accepted
AT*WIOP=50,100,2,1,3 OK
Change input type to be pulse
trigged
AT*WIOP?
*WIOP : TA = 50, TP = 100,
List parameters
TYPE = 2, TRIG = 1, NORM = 3
OK
AT*WIOP=?
*WIOP: (1-255), (1-255),
List command parameters
(0-4, 31, 32), (0-6), (0-4, 31, 32)
OK
ERROR Otherwise
S register: None