beautypg.com

Supervisory port, Power, Mechanical – Verilink WANsuite 5650 (34-00314.E) Product Manual User Manual

Page 62: Environmental, Alarms, Industry listings, Diagnostics

background image

A-2

W A N s u i t e 5 6 5 0

Supervisory Port

Connection:

DB-9 female

Data Rates:

(bps) 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
(default: 38400 bps)

Protocols:

VT100

Power

Voltage Input:

100–240 VAC

Frequency:

50 or 60 Hz

Dissipation:

10 W maximum (34.15 BTU/hour)

Current:

200 mA maximum

Mechanical

Mounting:

Stand-alone

Weight:

2.13 lb. (0.97 kg)

Dimensions:

Width 8.36 in. (21.234 cm)
Height: 1.65 in. (4.191 cm)
Depth: 9.11 in. (23.139 cm)

Environmental

Operating Temp:

32° to 122°F (0° to 50°C)

Storage Temp:

-13° to 158°F (-25° to 70°C)

Humidity:

96% maximum (non-condensing)

Alarms

Activation:

Programmable thresholds on all interfaces

Reporting:

Via SHDSL EOC or local management port

Industry Listings

Compliance:

CISPR 22 Class B

Safety:

EN 60950 (1992)

Diagnostics

Performance:

15-minute and 30-day monitoring (sampled every second)

Network Loops:

Line loopback or maintenance loopback (see Figures A-1
and A-2)

NOTICE:

All the following loopback diagrams show the loops as if the unit is
configured as an STU-R. If the unit were configured as an STU-C, the
Network and Customer sides would be reversed.