Rear Panel Connections

The rear panel of the WANsuite 5650 has five connectors. From left to right
(as shown in Figure 1.2 below) these connectors are the power port,
supervisory port, serial interface (Nx64k), G.703 port, and SHDSL port. The
connectors are described in detail in the following paragraphs.

Figure 1.2

WANsuite 5650 Rear Panel

Power Connection

The

POWER

port

is a standard grounded three-prong connector. This 100-240

VAC power receptacle is rated at 47–63 Hz. To apply power to the unit,
simply plug the supplied power cord into the unit’s

POWER

port and then

connect the wall plug to an appropriate electrical outlet. The unit has no
power switch.

When power is applied to the unit, the front panel indicators flash for
approximately 10 to 15 seconds as the unit initializes. The green

POWER

LED on the front panel will remain illuminated as long as the unit receives
power. This LED turns amber when the unit is in test mode.

CAUTION:

Always connect the power cord to a grounded electrical outlet.

Power Failure

If the

POWER

indicator does not illuminate, check the power connections and

the primary AC circuit breaker.

The WANsuite 5650 provides nonvolatile memory retention of the unit
configuration in case of a power failure. This feature allows the unit to
automatically restore normal service following a power loss.

NOTICE:

Because the WANsuite 5650 does not employ an internal battery or time
chip, the unit will not retain time and date information in the event of a
power failure. The unit marks time beginning at 00:00 with each power
cycle.