The table provides error status and alarm threshold information for the
following error parameters:
E S
Sets the Errored Seconds (ES) threshold. An ES is a 1-second period in which
at least one logic error occurred. The default threshold is 45 seconds.
S E S
Sets the Severely Errored Seconds (SES) threshold. An SES is a 1-second
period in which at least 320 CRC errors or one Out-of-Frame (OOF) error
occurred. The default threshold is 5 seconds.
L O S S
Sets the Loss of Signal Seconds (LOSS) threshold. A LOSS is 1-second
period in which the E1 received signal is interrupted. The default threshold is
5 seconds.
U A S
Sets the Unavailable Seconds (UAS) threshold. A UAS is a 1-second period
in which consecutive severely errored seconds cause an unavailable state. The
threshold is 0 (zero) seconds (Disabled).
C S S
Sets the Controlled Slip Seconds (CSS) threshold. The default threshold is 0
(zero) seconds (Disabled).
B P V S
Sets the Bipolar Violation Errored Seconds (BPVS) threshold. A BPVS is a 1-
second period in which at least one bipolar violation occurred. The default
threshold is 0 (zero) seconds (Disabled).
O O F S
Sets the Out of Frame Seconds (OOFS) threshold. An OOFS is a 1-second
period in which a frame sync loss occurred. The default threshold is 5
seconds.
A IS S
Sets the Alarm Indication Signal Seconds (AISS) threshold. An AIS is a 1-
second period when unframed all ones are received. The default threshold is 0
(zero) seconds (Disabled).
R A S
Sets the Remote Alarm Seconds (RAS) threshold. An RAS is generated by
the terminal equipment when an improper signal is received from the facility
(or upon receipt of unframed all ones). The default threshold is 0 (zero)
seconds (Disabled).
R eset T im er
The status table also provides an option for setting the Reset Timer threshold.
This field is the contiguous number of seconds that an alarm parameter must
be clear before the alarm is reset. Applicable values range from 000 through
900. A value of “000” means the alarm will never be reset. The default value
is 30 seconds.