beautypg.com

Local loop/error inject button, Remote loop button, Bert button – Verilink WANsuite 5650 (34-00314.E) Product Manual User Manual

Page 58

background image

4-2

W A N s u i t e 5 6 5 0

SELECT

button, the port’s corresponding LED will flash. The status of the

LLOOP

and

RLOOP

LEDs will be the summary of the test states for the port

interfaces.

The

PORT SELECT

button cycles through the following port options on each

successive press:

No port selection

Nx64k (serial interface) port

G.703 port

SHDSL port

When the Nx64k (serial interface) port is selected, the LED labeled

Nx64

flashes as an indication. The

LOCAL LOOP/ERR INJ

and

REMOTE LOOP

buttons initiate/terminate tests, and the corresponding LEDs indicate the status
of tests on this port only.

When on the G.703 port selection, the

G.703

port LED flashes as an

indication. The

LOCAL LOOP/ERR INJ

and

REMOTE LOOP

buttons initiate/

terminate tests, and the corresponding LEDs indicate the status of tests on this
port only.

When on the SHDSL port selection, the

SHDSL

port LED flashes as an

indication. The

LOCAL LOOP/ERR INJ

and

REMOTE LOOP

buttons initiate/

terminate tests, and the corresponding LEDs indicate the status of tests on this
port only. These tests are on the aggregate SHDSL payload.

NOTICE:

Port select will not operate if any locally initiated tests are in progress.

Local Loop/Error Inject Button

If a port is selected, pressing the

LOCAL LOOP/ERR INJ

button will place or

remove a local loop on the selected port.

Remote Loop Button

If a port is selected, pressing the

REMOTE LOOP

button will place or remove

a remote loop on the selected port.

BERT Button

This button is not applicable.