Alarm Profile Details Screen

The Alarm Profile Details screen (Figure 3.10) is accessed by moving the
cursor over a profile name in the Configuration Profiles screen and pressing
the “Enter” key. This screen is used to configure the alarm threshold values
to be used for the selected segment endpoint.

Figure 3.10

Alarm Profile Details Screen

P rofile N a m e

This field displays the unique index associated with this Alarm profile.

L oo p A tten u atio n

This field configures the loop attenuation alarm threshold. When the current
value exceeds this threshold, a crossing trap will be generated.

S N R M argin

This field configures the SNR margin alarm threshold. When the current
value drops below this threshold, a crossing trap will be generated.

E S

This field configures the threshold for the number of errored seconds (ES)
within any given 15-minute performance data collection interval. If the value
of errored seconds in a particular 15-minute collection interval reaches/
exceeds this value, a trap will be generated. One trap will be sent per interval
per endpoint.

S E S

This field configures the threshold for the number of severely errored seconds
(SES) within any given 15-minute performance data collection interval. If the
value of severely errored seconds in a particular 15-minute collection interval
reaches/exceeds this value, a trap will be generated. One trap will be sent per
interval per endpoint.

C R C

This field configures the threshold for the number of CRC anomalies within
any given 15-minute performance data collection interval. If the value of
CRC anomalies in a particular 15-minute collection interval reaches/exceeds
this value, a trap will be generated. One trap will be sent per interval per
endpoint.