Verilink WANsuite 5650 (34-00314.E) Product Manual User Manual
Page 17

A b o u t t h e W A N s u i t e 5 6 5 0
1-5
Table 1.1
LED Indicators
LED Label
Off
Green
Amber
Red
POWER
No Power
Power applied to unit
Unit in test mode.
SHDSL
Mains Power Off
Trained with good
signal quality
Trained with marginal
signal quality
Training or attempting
to train with poor
signal quality and/or a
major network port
alarm is active
G.703
Service not configured Service configured and
interface is operating
normally
Service is configured
and has minor alarms:
RAI; Slip
Service configured and
interface is not
operating normally:
LOS; LOA; AIS.
Nx64
Service not configured Service configured and
interface is operating
normally
Service configured and
interface is not
operating normally or
port mismatch
RTS/C
Nx64k service not
configured or RTS/C
control line is OFF
"RTS" or "C" control
line (from DTE) is ON
RLSD/I
Nx64k service not
configured or RLSD/I
control line is OFF
"RLSD" or "I" control
line (from DTE) is ON
LLoop
No loop present
A local loop is active
on the selected
customer port
(button controlled)
A local loop is active on
the selected customer
port
A local loop is active
on the SHDSL port
RLoop
No loop present
A remote loop is active
on the selected
customer port
(button controlled)
A remote loop is active
on the selected
customer port
A remote loop is active
on the SHDSL port
BERT
not applicable
not applicable
not applicable
not applicable