beautypg.com

Span endpoint maintenance screen, Span endpoint maintenance screen -16 – Verilink WANsuite 5650 (34-00314.E) Product Manual User Manual

Page 38

background image

3-16

W A N s u i t e 5 6 5 0

3.13), Span Endpoint Performance Screen(s) (Figure 3.14), and the Alarm
Profiles screen (Figure 3.9).

Span Endpoint Maintenance Screen

The Span Endpoint Maintenance screen (Figure 3.13) is accessed by moving the
cursor to the “Maintenance” field in the Span Endpoint Details screen and
pressing the “Enter” key. This screen supports maintenance operations (e.g.,
loopbacks) to be performed on segment endpoints.

Figure 3.13

Span Endpoint Maintenance Screen

The Span Endpoint Maintenance parameters are described as follows:

L oop b ack Typ e

This field controls configuration of loopbacks for the associated segment
endpoint.

Values:No Loopback, Normal Loopback, Special Loopback
Default:No Loopback

NOTICE:

Only the Normal Loopback option has been implemented for the
WANsuite 5650.

L o op b ack T im eo u t

This field configures the timeout value in minutes for loopbacks initiated at
segments endpoints contained in the associated unit. A value of 0 (zero)
disables the timeout.

T ip R in g

This field indicates the state of the tip/ring pair at the associated segment
endpoint.

P o w er B a ck off

This field configures the receiver at the associated segment endpoint to
operate in default or enhanced power backoff mode.

Values:Default, Enhanced
Default:Default