beautypg.com

9 - general preferences, Global preferences, Mixer preferences – Teac 2488 User Manual

Page 84: 9 – general preferences, Fader matching

background image

84

TASCAM 2488

User’s Guide

9 – General preferences

There are four sets of general preferences that you
can make in order to customize the 2488 to your
working style.

Access all of these through the

PREFERENCES

menu.

Global preferences

These all affect the overall operation of the 2488

Key sense time

Some of the keys on the unit

have two different functions, spending on whether
they are pressed and released in a short space of time,
or whether they are pressed and held down for a
longer period.

The pitch control is a good example of this. If the

PITCH/SSA

key is pressed and released briefly, the

pitch control is turned on. If it is pressed and held for
the time set here, a screen appears allowing you to
make the settings for the pitch and the slow speed
audition functions.

The setting for the key sense time is from 0.3 to 2.0
seconds, in 0.1 second steps.

Meter peak hold time

The meters shown on

the home display and other pages can be configured
to hold the peak value.

This parameter can take the following values:

OFF

,

where the meters do not hold the peak value at all,

ON

; the peak meters hold the value for a second or so

and then drop back, or

KEEP

, where the peak value is

always shown on screen until this value is changed.
You can also use

SHIFT + HOME

to clear these held

peak values.

Use the cursor keys to highlight the parameter, and
the wheel to change it

TIP

\

The

KEEP

setting is useful if you want a permanent

record of the highest value, but you cannot keep your
eyes on the meters during the whole take or rehearsal.

Meter release time

The meter “drop-back”

time can be configured to be from 3

0ms

to

100ms

in

10ms steps using the cursor keys to highlight the
parameter, and the dial to change it.

Note that the meters are always peak meters, and the
rise time is fixed.

Shift key behavior

The

SHIFT

key can be used

in one of three ways, as set by this parameter:

AUTO

SAFE

, in which the

SHIFT

key can be pressed and

released, and remain active for about a second; and

UNLOCK

, in which the key is non-latching; that is, you

must press and hold the

SHIFT

key while pressing

the other key to be shifted. The

HOLD

setting latches

the

SHIFT

key on until another key is pressed.

Mixer preferences

As the name says, these affect mixer items:

Fader matching

The option affects the way in

which the physical and the virtual faders interact (see
“Faders” on page 24). There are three options here:

REAL

: if the internal fader level is changed using a

scene change or a MIDI Control Change, this is
ignored. The actual physical fader is the only way
in which the fader level is set.

JUMP

: the internal fader level jumps to the level set

by the physical fader as soon as the physical fader
is moved. Since this can result in sudden changes
in volume, resulting in possible damage to hearing
and monitoring equipment, this option should be
used with caution.