beautypg.com

10 – internal settings, Setup page – Teac HS-20 User Manual

Page 83

background image

TASCAM HS-20

83

10 – Internal settings

Touch the GENERATOR item EDIT button or the user bits (UB)

display area to open the T/C USER BITS screen.
When the timecode generator is in free run mode, touch

the RESTART button to reset the timecode of the timecode

generator to the start time.

TC IN

The top line shows the time of the input timecode and the

frame type. The bottom line shows the user bits (UB) of the

input timecode.
In FREE RUN mode, touch the CAPTURE button to capture

the current timecode and set it as the timecode of the

timecode generator.
If the timecode generator mode is FREE ONCE or JAM SYNC,

the capture status (WAITING) indicator lights green when

waiting for timecode, and it turns off after timecode is

captured.

START TIME

When you touch the GENERATOR item RESTART button, the

time when the timecode restarts is shown.
Touch the START TIME item EDIT button or the START TIME

display area to open the START TIME screen.

SETUP page

Make settings related to the timecode generator on this page.

STATUS

Set the current timecode frame type.

TC GEN MODE

Use theses buttons to set the timecode generator mode.

NOTE

If an optional SY-2 has not been installed, the items will be

shaded and cannot be set.

FREE RUN button:

The timecode generator runs on its own.

FREE ONCE button (default):

After the input timecode is captured once, the unit starts

free run mode.

TIME OF DAY button:

If you conduct any of the following operations, the time

will be captured from the internal clock and free run

mode will start.

o

Turn the power on

o

Set TC GEN MODE to this mode

o

Reset the internal clock

JAM SYNC button:

When timecode is input, the unit synchronizes to it. If

timecode input is interrupted, the unit enters free run

mode.

REGEN button:

The unit synchronizes to the input timecode.

REC RUN button:

The timecode generator only functions during recording.

At all other times, the timecode generator stops.

Frame Type

Use to set the timecode frame type.
Setting buttons: 23.976F, 24F, 25F, 29.97DF (default),

29.97ND, 30DF, 30ND