Super Systems 9200 User Manual
Page 59
Model 9200 Programmable Dual-loop Controller
SSi Manual SERIES 9200
59 Programmable Dual-loop
Events Instruments
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
AC20 50
310
1
1
Events
Actual
(Modbus Mode)
50
310
1
1
Events Setpoint
49
300
1
1
Events
Input
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Yoko 750
49
310
1
1
Events Actual
(Modbus Mode)
49
310
1
1
Events Setpoint
49
310
1
1
Events
Input
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
ModMux 97
97
1
1
Events
Actual
(Modbus Mode)
97
97
1
1
Events Setpoint
98
98
1
1
Events
Input
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Dualpro Events
59
178
1
1
Events Actual
(Modbus Mode)
49
168
1
1
Events Setpoint
59
178
1
1
Events
Input
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Dualpro Events
82
178
1
1
Events Actual
(MMI Mode)
72
168
1
1
Events Setpoint
82
178
1
1
Events
Input
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Carbpro 3.5 Events
8
43
1
1
Events Actual
(MMI Mode)
2
17
1
1
Events Setpoint
8
43
1
1
Events
Input
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Carbpro 3.0 Events
8
43
1
1
Events Actual
(MMI Mode)
2
17
1
1
Events Setpoint
8
43
1
1
Events
Input
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Eurotherm 2500
19
19
8
8
PV
(Modbus Mode)
5
5
1
1
Setpoint Loop 1
40
40
1
1
Percent Output Loop 1