Super Systems 9200 User Manual
Page 13
![background image](https://www.manualsdir.com/files/806376/content/doc013.png)
Model 9200 Programmable Dual-loop Controller
SSi Manual SERIES 9200
13 Programmable Dual-loop
Quench / Zone Instrument Assignments (Read-only)
The Quench / Zone Instrument Assignments
Display shows two groups of information,
both of which are dependent on
CONFIGURATION or OPT CODE use. The
quench portion will only display if the
quench opcode was executed in a program.
This will then show the total quench time,
the time remaining, and the quench speed.
The zone group will display the process
variables that have been assigned in the
zone assignment configuration.
Chart
The Chart Display shows between 15 minutes and 7 days of process variable data on the screen, and can
be scrolled back to view all of the data stored on the hard drive (72 hours at a time). The vertical timelines
change as the time changes on the screen. A chart is available for the LP1 and LP2 only and a chart is
available for the LP1 and LP2 plus their set points. You can toggle between the two charts by pressing the
PREV and the NEXT keys.
The Prev and Next arrows
change the display from one chart
to another (i.e. from just process
variables to process variables and
set points.)
The blue RIGHT and LEFT
arrows move the displayed chart
along the horizontal axis, going
back and forward in time and
then returning to real time.
The + and – keys change the
time window displayed on the
screen.
The Note key allows the operator
to enter a note on the chart,
similar to writing on a paper
chart. The note shows up when
the chart is printed out using the
utility software included with the
Series 9200 instrumentation. The interface must be the ADVANTECH 5.7-inch with the Flash Card.