Super Systems 9200 User Manual
Page 53
Model 9200 Programmable Dual-loop Controller
SSi Manual SERIES 9200
53 Programmable Dual-loop
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Eurotherm 2404
1
1
1
1
%C Actual
(Modbus Mode)
5
5
1
1
%C Setpoint
72
11073
1
1
Probe
Temperature
61
11062
1
1
Probe
Millivolts
4
4
1
1
%C Percent Output
0
0
1
1
CO Factor or Equivalent
0
0
1
1
H Factor or Equivalent
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Eurotherm 2500
1
1
1
1
%C Actual
(Modbus Mode)
5
5
1
1
%C Setpoint
72
11073
1
1
Probe
Temperature
Assumes Loop 1 =
61 11062
1 1
Probe
Millivolts
Atmosphere
4
4
1
1
%C Percent Output
68
11069
1
1
CO Factor or Equivalent
68
11069
1
1
H Factor or Equivalent
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Carbpro 3.5
6
28
1
1
%C Actual
(MMI Mode)
1
1
1
1
%C Setpoint
5
25
8
8
Probe
Temperature
4
24
8
8
Probe
Millivolts
11
117
1
1
%C Percent Output
13
7
1
1
CO Factor or Equivalent
14
8
1
1
H Factor or Equivalent
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Carbpro 3.0
6
28
4
4
%C Actual
(MMI Mode)
1
1
1
1
%C Setpoint
5
25
8
8
Probe
Temperature
4
24
2
2
Probe
Millivolts
11
117
1
1
%C Percent Output
13
7
1
1
CO Factor or Equivalent
14
8
1
1
H Factor or Equivalent
Controller Source
Location
Write
Register
Read
Scale
Write
Scale
Description
Carbpc 20
20
1
1
%C
Actual
(MMI Mode)
6
6
1
1
%C Setpoint
17
17
8
8
Probe
Temperature
18
18
8
8
Probe
Millivolts
64
64
41
41
%C Percent Output
3
3
1
1
CO Factor or Equivalent
4
4
1
1
H Factor or Equivalent