Leakage
75
Leakage
Range...........................................................................0.1mA - 10.0mA
Resolution.............................................................................0.01mA
Accuracy................................................ +/- 5% of reading, +/- 2 digits
Pass Levels.....................0.25mA, 0.5mA, 0.75mA, 1.5mA, 2.25mA,
2.5mA, 3.0mA, 3.5mA, 9.9mA
Touch Leakage
Range.............................................................................0.1mA - 2.0mA
Resolution.............................................................................0.01mA
Accuracy.............................................. +/- 10% of reading, +/- 2 digits
Pass Levels...................................................0.25mA, 0.5mA, 1.0mA
Power Tests
Socket......Selectable 115V BS4343, BS546 / 230V BS 1363 socket.
Measured Voltage................................................................. 90 - 300V
Indication only.
Measured Load ....................................................................... 0 - 4kVA
Indication only.
IEC Lead Test
Test Voltage *…40Vac or 250Vdc depending on hardware revision
Detects..................................................... Open, Short, Good, Reverse
* - Test stimulus based on mains supply of 230V, varies with supply
voltage.