Downloading to Computer Software

69

Comparing Flash test results with other testers

To comply with forth coming test standards the Flash output current
has been limited. The actual current displayed with differ from
previous testers as illustrated in the table below.

Load Previous

Testers

Supernova

3M ohms

0.5mA

0.43mA

1.5M ohms

1mA

0.75mA

750K ohms

2mA

1.2mA

500K ohms

3mA

1.5mA

300K ohms

5mA

1.87mA

The Flash pass/fail limits have been adjusted from 3mA and 5mA to
1,5mA and 2mA respectively.