2 cable specification, Remko fresh water station controller, Cable specification – REMKO EFS 25-35 User Manual
Page 8

Unit data (continued)
Series
EFS 25-35
Physical values
Dimensions L x W x H
mm
110 x 160 x 51
Weight
g
350
Software class
A
Mode of operation
Type 1.Y
Fastening method for permanently-con-
nected lines
Type X
Degree of contamination
2
Temperature of the ball pressure check
Housing walls: 125 °C
Remaining housing parts: 75 °C
Overvoltage category
Class II (2500 V)
2.2
Cable specification
Mains cable
Mains power supply type
Outer diameter of jacket
Single wire cross section (rigid)
finely-stranded (with wire end sleeves)
H05 VV-... (NYM…)
6.5 mm to 10 mm
≤ 2.5 mm
2
≤ 1.5 mm
2
Diameter of the internal strain relief
mm
6.5 to 10
Signal cable
Length of probe cable
m
≤ 100 m, including extension
Extension cable for probe configuration
Cross-section per conductor
Wires twisted in pairs for length > 10 m
0.75 mm
2
for length < 50m
1.5 mm
2
for length > 50 m
REMKO fresh water station Controller
8