2 technical data, 1 unit data, Technical data 2.1 unit data – REMKO EFS 25-35 User Manual
Page 7: Technical data, Unit data

2
Technical data
2.1
Unit data
Series
EFS 25-35
Inputs/outputs
Rated voltage (system voltage)
V / Hz
115... 230V / 50/60 Hz
Energy consumption
W
≤ 0.8 W, two Pt1000 temperature probes connected
Outputs R1, R2 - number
Type
Switching current
Voltage
2
Triac
2.0 (2.0) A
115... 230V / 50/60 Hz
L
const
- Switching current
Voltage
2.0 (2.0) A
115... 230V / 50/60 Hz
Total - Switching current
Voltage
4.2 (4.2) A
115... 230V / 50/60 Hz
Signal inputs/outputs
Signal inputs 1 ... 5 - Number
Type of signal inputs 1 ... 4
Type of signal input 5
5
Pt1000 (temperature detection)
Bus communication for cascading
Signal output R
S
type
Maximum contact rating
Potential-free NO contacts
1 (0) A, 24 V
Signal outputs PWM R1, PWM R2 - type
Maximum load capacity
PWM, 250 Hz, 11 V;
Characteristics: 0 % PWM = Pump off
100 % PWM = Maximum speed
10 mA
Hydraulic variants
Number
5
Display
Type
LCD with background illumination
Operating conditions
Enclosure class
IP 22, DIN 40050 [without front panel: IP 20]
Protection class
I
Ambient temperature
°C
0 ... +50 °C for free wall mounting
7