Fig. 21: Distribution valve in return flow

Measured value display: The measured values are

displayed in the status menu. The temperature of

the cold water probe and the operating hours of

the distribution valve are displayed after the fresh

water values.

Temperature of the cold water probe: The corre-

sponding minimum/maximum value is displayed

when "SET" is pressed.

Fig. 22: Display of minimum/maximum value

Operating hours of the distribution valve: When

"SET" is pressed, the delta value and the cumula-

tive value of the operating hours are displayed

alternately.

Fig. 23: Display of the delta value and the cumula-

tive value of the operating hours

In cascade operation, this function may only be

activated for the master controller. This func-

tion is blocked in the slave controller. The slave

controller sends its cold water temperature to

the master controller. If both stations are

active, the higher cold water temperature is

used as the switching value.

Key variable

min. max.

Factory setting

Activation

on, oFF

oFF

Sliding hot water temperature

Adjusts the domestic hot water target temperature

to the temperature level of the buffer tank for pre-

heating systems that are discharged from the

Buffer tank without re-heating

(Tww target = T

VL

- 5 K).

This function works according to fixed parameters.

No further settings are required. If this function is

active in operation, this is symbolised by a flashing

temperature.

The function can only be activated or deactivated.

Fig. 24: Sliding hot water temperature

In cascading operation, this function is recom-

mended only in exceptional cases because

high temperature fluctuations occur at the dis-

pensing connection when switching the mod-

ules. If the function is selected despite this, it

must be activated in the master and slave con-

trollers. The function works independently in

each of the controllers.

Key variable

min. max.

Factory setting

Activation

on, oFF

on

21