2 group controllers, Group controllers – Proel PRONET v.2.1 User Manual
Page 71
71
Fig.91 Toolbar link enable.
Note that when you connect different devices in a PRONET network they could come with different setups,
which means that the parameters on their presets can be really different. Assigning devices to the same
group and enabling the link doesn’t automatically align all the parameters of the devices grouped, the
parameter are aligned only when they are modified!
A good way to align the parameters for all devices in a group can be obtained recalling a preset or download
a Data File: after this operation all devices are aligned and right to be programmed.
Linked operations are available only for devices assigned to the same group, which have to be also of the
same type or of homogeneous type. This means that you can assign a subwoofer and a full range
loudspeaker to the same group but they do not perform linked parameter changes. Vice versa it’s possible
to assign different types of full range loudspeaker (for example NEOS12AXS and NEOS15AXS) to the same
group and obtain the linked parameter changes, because they are homogeneous devices: devices of the
same family (NEOS AXS) and of the same category (full range loudspeaker).
9.2.2
Group controllers
When you assign a Group Controller to one or more groups, you can control their basic Level, Mute
parameters and Preset Change for different groups.
Group Controllers can be opened by the
Menu→Groups→Add Group Controls
option and they are visualized in
Fig.92 and Fig.93.
To remove a Group controller follows the
Menu→Groups→Remove Group Controls
option.
Fig.92 Group Controller: Control Panel.
Fig.93 Group assignment for a controller.
In the “Control” graphic interface you can manage:
1.
Input level (by the slider or the edit box)