beautypg.com

Device parameters, Routing configuration, Digital input trim (available only for pc260) – Proel PRONET v.2.1 User Manual

Page 51

background image

51

6.10

Setup page

Fig.67 Edit page for general setup page.

The “Setup” page shows the internal processing structure of the PC240/PC260 devices and it can also control

some other general settings:

Device parameters

Device Name: the name of the device, used to easily recognize the device in a network, it is also visualized in

the Control Panel display (see ”Desktop window and control panels” section), in the Devices Tree Window

(see “Device Tree window” section) and in the display of the remote PC240/PC260.
Device Group: assigns the device to one of the available groups (see “Groups and links” section).

Routing configuration

Input routed from: (available only for PC260) select the input source from Analog Input (A-B XLR input

connectors) or Digital Input (L-R AES/EBU input connection).
Out routed from: this option selects the routing of each output channel (A, B and A+B options).
Note: The sum option (A+B) is taken after the whole processing of input A and B channels. If they are not

ganged and the processing is different for both channels then the result can be unpredictable.

Digital Input Trim

(available only for PC260)

Adjusts the level of the Digital Input (AES/EBU input connection). The Digital Input level can be adjusted from

-22dB to +6dB with 2dB steps.