Connect sf-3050 to pc, Figure 40: internet protocol window – NavCom StarUtil-3000 Rev.A User Manual
Page 36

StarUtil-3000 User Guide – Rev A
Refer to Figure 40 for the steps below:
6. Select the option, Use the following IP address.
Figure 40: Internet Protocol Window
7. Enter the IP address for the PC. In this case, enter 192.168.0.100
The first part of the IP address, 192.168.0, is the same for the SF-3050 and the PC.
The last part of the IP address must be unique for every device. In this case, it is 100
for the PC.
8. Press the Tab button on the keyboard. The Subnet mask is automatically populated.
9. Click
the
OK button in this window and also in the Local Area Connection window.
10. Continue to the next section for connection instructions.
Connect SF-3050 to PC
1. Open
StarUtil-3000.
2. Click
the
Connections button to establish communications between the PC and the
SF-3050 (see Figure 28). The Port Configuration dialog box opens.
Refer to Figure 41 for the steps below:
3. Select
Ethernet as the Connection Type.
Do not change the default Ethernet Settings: 192.168.0.2 is the factory default IP
address of the SF-3050. The default virtual COM port is 4361.
2-34